Equipment: JK-AAS-361MC Atomic Absorption Spectrophotometer
Equipment Type: Metering Equipment
Unit Type: set
Technical Parameters: Wavelength range: 190nm-900nm Wavelength accuracy: ≤±0.5nm Wavelength repeatability: ≤0.3nm ( single direction)
Post Time: 2016-07-20
Main Features: Multi-function: the computer automatically deduct blank value, the sensitivity drift and baseline drift, automatically calculate mean and deviation,and equation of working curve and read out the concentration, automatically print working reports, but also make analysis on based of flame emission spectrophotometry , hydride atomic absorption spectrometry and on-line preconcentration flow injection atomic absorption method. Unique light path design Reliable flame safety system Automatic four-lamp turret system Small flame structure analysis system Multi-Functional software working station Micro-computer automatically control operation system Multi-functional flame atomic system High efficent and sensitive stomic system Simple operation: Just hit a key two times only after setting up, can automatically read out/print out the absorbance and concentration values and relative standard deviation. Compared with non-computer equipment, save a lot of manual data processing time. Stable signal: high-quality photomultiplier tubes imported and advanced integrated circuits, single-beam optics, strong light monochromator and high efficient atomizer, ensure the strong energy, low noise and good accuracy in the whole band, accurate transformation, no drift, stable baseline Fine peak searching: the special wavelength adjustable system can accurately align the peak wavelength position Continuous slit:original continuous slit institutions ensure the best sepctral resolution and high bandwidth.
Usage:
Description: Wavelength range:190nm-900nm Wavelength accuracy:≤±0.5nm Wavelength repeatability:≤0.3nm(one way) Resolution ability:Mn Distinguish:Two-time trough<40%( spectral bandwidth at 0.2nm) Baseline stability:better than 0.004A/30min(copper) The detection limit:≤0.008ug/ml(Copper) Characteristic Concentraton:
Inquiry
Recipient: Joy Company: Shanghai Jingke Scientific Instrument Company
Title: *    
Content: *
Contact
Name: * Company: *
Tel: * E-Mail: *
Fax: WebSite:
  
Copyright©Chemamde Contact us Tel:0086 21 34637407 Fax:0086 21 34637410